Description
System Specification
- Designed for 5X & 10X dilution of buffer solution with WFI water. Customized solutions and designs are available to take up to 20X
- Flow rate range of 100 – 5000 LPH with an accuracy of ± 1%
- Conductivity control with an accuracy of ± 1%
- Mixing and control loop for pH control
- Dedicated acid and base dosing pump for precise pH control
- Sterile filtration before outlet with provision for in-situ integrity testing
- In-line heat exchanger for temperature control
- Provision to do CIP of all fluid paths & SIP of Sterile filters
- Advanced control mechanism
- 21 CFR part 11 Compliance system
- PLC and SCADA-based system
FAQs
1. Are the customized solutions limited to specific industries?
Our customized solutions are referred to the pharmaceutical industry, bio-pharmaceutical industry, food industry, and consumer packaged goods industry.
2. Are your systems meeting the regulatory norms?
Yes, our high purity water systems are compliant with your required regulatory norms like USP, EP, JSP, TGA, etc.
3. Is there any option to check the feasibility of the technology for my product?
Yes, we have a process development lab where feasibility, optimization, and scale-up studies can be performed using the entire range of membrane systems and chromatography systems. We provide customized solutions and technologies that are highly feasible based on your industry.
4. Is the Bio Kill system important for my industry?
Industries with continuous processes may benefit from a Bio Kill system to ensure ongoing microbial control and prevent disruptions. If your industry produces sensitive products, such as pharmaceuticals, where microbial contamination can compromise product efficacy or safety, a Bio Kill system becomes crucial to maintain product quality.